1.23.14 05469E © Inovonics, 2014 - www.inovonics.com
EN1262 EchoStream® Passive Infrared Motion
Detector
Installation and Operation Manual
1 Overview
The EN1262 is a low-current motion detector highly sensitive to moving
heat (infrared radiation) sources.
1.1 Inovonics Contact Information
If you have any problems with this procedure, contact Inovonics technical
services:
E-mail: [email protected]
Phone: (800) 782-2709; (303) 939-9336
1.2 What’s in the Carton
One Duracell DL123A 3.0V battery
Two selection jumpers
Two mounting drywall anchors
Two mounting screws
Two housing screws
One tamper wall anchor
One tamper rivet
1.3 Passive Infrared Motion Detector Internal
Components
Figure 1 EN1262 Components
2 Installation and Startup
2.1 Installation Notes
These products are designed to be maintained by professional
security technicians
Products are tested for indoor use
All products should be manually tested weekly
2.2 Mount the Housing
1. Insert a small flat-blade screwdriver at the tab on the bottom of the unit.
The screwdriver will enter the slot at about a 45° angle. Press
downward on the handle of the screwdriver until the latch holding the
cover to the housing base releases.
Figure 2 Open the housing
2. Pull the circuit board attachment latch and lift the circuit board out of the
housing.
Figure 3 Circuit board attachment latch
3. As desired install the wall tamper rivet.
Note: Wall tamper installation is required for BSI Class VI.
a. Use a 3/16” (4.8mm) bit to drill out the tamper rivet hole index.
b. Install the tamper wall anchor in the wall where you will be mounting
the motion detector’s tamper rivet.
c. Use a hammer to tap a rivet into place in the tamper wall anchor.
Figure 4 Mounting hole indices
A Wall tamper
selection pins
B Housing tamper
switch
C Frequency band
selection pin
D Reset button
C
A
B
D
A Tamper rivet index B Corner mount index C Wall mount index
Circuit board
attachment
latch
A
BB
B
B
C
B
B
C
C
Seitenansicht 0
1 2 3

Inhaltsverzeichnis

Seite 1 - Detector

1.23.14 05469E © Inovonics, 2014 - www.inovonics.comEN1262 EchoStream® Passive Infrared Motion DetectorInstallation and Operation Manual1 OverviewThe

Seite 2 - 5 Specifications

1.23.14 05469E © Inovonics, 2014 - www.inovonics.com 24. Mount the housing, using either the three wall-mount holes or the four corner-mount holes.a.

Seite 3 - 8 Warranty and Disclaimer

1.23.14 05469E © Inovonics, 2014 - www.inovonics.com 3• Connect the equipment into an outlet on a circuit different from that to which the receiver i

Kommentare zu diesen Handbüchern

Keine Kommentare