Inovonics FA116 Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 21
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
© 1997 INOVONICS Corporation
8
LIT-FA116-USER 01860
Programming C404 Slave Receivers
Press
ENTER
to program or modify transmitter settings.
Press
Å
ÅÅ
Å
to go to
DELETE POINTS
menu option or
Æ
for
RECEIVER SETUP
.
Enter point number from keypad. Press
ENTER
.
Is the transmitter a C100 Commander?
Arrow keys toggle between
YES
and
NO
.
Is the external switch loop normally open or closed?
Arrow keys toggle between
NORM/OPEN
and
NORM/CLOSED
.
Is a 2.2K end of line resistor being used to monitor the switch loop?
Arrow keys toggle between
NO
and
YES
.
Is C200W widegap magnet contact being used? Arrow keys toggle
between
NO
and
YES
.
How often should supervisory data be transmitted?
Arrow keys toggle between
UNSUPERVISED
and
10, 30,
or
60 SECONDS
.
Press
ENTER
to proceed with transmitter programming,
or press
A
to go through transmitter options again.
Connect transmitter and press transmitter reset to program device, or press
A
to save point program and select a new point number.
Indicates successful transmitter programming sequence. Display remains for
about 3 seconds, then returns to the point number selection screen.
POINT NUMBER:
ENTER #(1 to 4)
4-BUTTON TX:
Å
YES
Æ
ENTER TO PROGRAM
"A" to REVIEW
RESET TX+CONNECT
OR PRESS "A"
POINT NUMBER nn
TX PROGRAMMED
CHECK-IN TIME
Å
60 SECONDS
Æ
USE INTERNAL
CONTACT:
Å
NO
Æ
END OF LINE
RESISTOR:
Å
NO
Æ
EXT SWITCH TYPE
Å
NORM/OPEN
Æ
Program
Points
Press ENTER to
Å
PROGRAM POINT
Æ
THESE OPTIONS
ARE SKIPPED IF
4-BUTTON TX
= "YES"
Seitenansicht 9