1 Overview
The Inovonics EE1215W door/window transmitter with
wall tamper and reed switch comes with a magnet that
supports a 16mm (5/8”) gap, and can also monitor one
normally open or normally closed external contact. The
EE1215W has both case and wall tamper switches, and
the housing can be secured with screws.
Note: If you are using an add-on receiver, you must use
the reed switch.
The EE1215W is compliant with:
EN50131-2-6
Security Grade 2
Environmental Class II
1.1 Inovonics Contact Information
If you have any problems with this procedure, contact
Inovonics technical services:
E-mail: [email protected]
Phone: (800) 782-2709
1.2 EE1215W Components
Figure 1 EE1215W components
2 Installation and Startup
2.1 Install/Replace the Battery
1. If replacing the battery, remove the housing screw.
2. Insert a small screwdriver to depress the housing
release tab on the bottom of the transmitter; twist the
screwdriver to open the housing.
Figure 2 Open the EE1215W Housing
3. If replacing a battery, remove the old battery.
4. Install the new battery.
5. Press the Reset button to initialize the transmitter.
6. Test the transmitter and ensure appropriate response.
2.2 Select Input Type
The NO/NC selection pins select a normally open (NO) or
normally closed (NC) state for the contact circuit wired to
the input terminal.
1. Place a selection jumper on the NO/NC selection pins
to select normally open; leave the jumper off the pins
to select normally closed.
2. Press the Reset button.
Caution: If only the reed switch is to be used, normally
open must be selected for the external contact.
2.3 Select the EchoStream Select Compatibility
To meet ETSI requirements, Inovonics has developed a
new line of EE 868MHz-only products. These new
868MHz-only products are compatible with older systems
that include EchoStream select products. If you are using
any ES products in your current system, you will need to
enable EchoStream select compatibility on this new
868MHz-only product.
To enable/disable EchoStream select compatibility:
1. To enable compatibility with ES products, place a
selection jumper on the enable EchoStream select
compatibility selection pins.
2. If no ES products are used in your system, remove the
selection jumper from the EchoStream select
compatibility selection pins.
3. Press the Reset button.
2.4 Register the EE1215W
Transmitters must be registered with the system in order
to be monitored and supervised. When supervised, the
transmitter will send a check-in message to the receiver.
Transmitters using the 868MHz frequency range for
Europe will send a check-in message every 12 minutes;
all other transmitters will send a check-in message every
three minutes. Each transmitter has a unique factory-
programmed identification number. Refer to the receiver
installation instructions for details on registering a
transmitter.
1. When prompted by the receiver to reset transmitter,
press the Reset button.
2. Test the transmitter and ensure appropriate response.
2.5 Mount the EE1215W
1. Choose a mounting location that will allow the magnet
to be located parallel to the transmitter such that there
is no more than a 16 mm (5/8”) gap between it and the
internal contact magnetic reed switch, and on a non-
ferromagnetic surface.
2. Route the external wiring through the wall, as shown
in Figure 3.
Figure 3 Mount the Transmitter to the Wall
3. Mount the transmitter to the wall using the the wall-
mount screw holes, ensuring the housing is flush
against the wall and the wall tamper switch is firmly
depressed.
4. Close the housing.
5. Mount the magnet on a non-ferromagnetic surface so
that it is parallel to the transmitter with no more than a
16mm (5/8”) gap between it and the internal contact
magnetic reed switch.
6. Secure the housing through the enclosed housing
screw hole.
A Housing tamper button B NO/NC selection pins
C Input terminal D Reset button
E Wall-mount screw holes F Housing screw hole
G EchoStream select
compatability selection pins
H Reed switch
I Transmit LED
A
B
C
D
E
F
G
E
I
H
Twist the
screwdriver to
open the
housing
Wall Tamper
Switch
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Door/Window

«=fåçîçåáÅëI=OMNM=J=ïïïKáåçîçåáÅëKÅçãEE1215W EchoStream® Door/Window Transmitter with Wall Tamper and Reed SwitchInstallation Instructions - 04932C1 O

Seite 2 - 4 Warranty and Disclaimer

3 SpecificationsExternal contacts: N/O or N/CDistance, external contact to transmitter: 3m (10 ft) maximumMounting distance, magnet to internal magnet

Kommentare zu diesen Handbüchern